World: r3wp
[Core] Discuss core issues
older newer | first last |
Janeks 10-May-2005 [1057x3] | O'k. My mistake are offen do not tell what is my target. So it is to get working status bar in a layout. As I understood it is possible by read-thru. |
Thanks Gabriele. It was the reason. But to continue regarding status bar functions fired by read-thru. Than it is a problem just to kBox/image: read-thru/progress myUrl :myProgr . It is possible just by using local file i.e. kBox/image: read-thru/to/progress myUrl %tmpImg.png :myProgr | |
BTW: How to insert newline in a post? | |
DideC 10-May-2005 [1060] | Click the "pen" icon just up to the input area (near color/ no color one) |
Janeks 10-May-2005 [1061] | Thanks! I am getting following parameters of myProgr: 3650 8000 7430 8000 9950 8000 13730 8000 15335 8000 19115 8000 22975 8000 26755 8000 30695 8000 34475 8000 38255 8000 42195 8000 46055 8000 49835 8000 53695 8000 55197 8000 55197 8000 How then to calculate data for progress bar ( decimal from 0 to 1 )? Or how to get total bytes? |
Allen 10-May-2005 [1062] | Janek. request-download has the example callback you need. View its source. here is a snippet. Where prog is the progressbar and stat is a label in your layout and stop is a value that controls that should be be set false outside of this func to start with, and can set to true via a cancel button to force a download to stop before completion. func [total bytes] [ prog/data: bytes / (max 1 total) stat/text: reform [bytes "bytes"] show [prog stat] not stop ] |
Janeks 11-May-2005 [1063] | Thanks Allen! The problem was so obvious that I did not think about it ;-) just it is impossible to know what size of image will be that is coming from a cgi process with many parameters. |
Allen 11-May-2005 [1064] | A easy job for REBOL... http://www.eyon.com/. I can't believe this tool needs to be 4mb zipped. |
Volker 12-May-2005 [1065] | i like this little function and cant find a good name. your: func [offset value] [ if value [value/:offset] ] usage: your 'facet get-style 'field its sometimes more readable IMHO than putting the interesting word far at the end of line. but i find no good name.. any suggestions? |
RebolJohn 12-May-2005 [1066] | Help peoples.. I have the following.. x: [a b c d] foreach y x [ set y make string! {} ] ;make them all empty strings. then I process/append info into the different groups a,b,c,d. Now, I want to write each string/list to a file of the same name. i.e. foreach y x [write to-file join y ".txt" ??GETVALUE?? y] Can someone clue me in on what I do at the ??GETVALUE?? position? Thanks peoples. |
Sunanda 12-May-2005 [1067x2] | foreach y x [print [y get y]] |
... so the missing ??getvalue?? is just get | |
Graham 12-May-2005 [1069x2] | How does one open up the serial port? I've tried open serial://port1/9600/8 and serial://port1/9600/8 and both give me errors .. |
this is in windows | |
Anton 12-May-2005 [1071x3] | Volker, in english, it seems better to write 'facet of face (where OF is the function in between) but we can't do that... How about TAKE ? ie. take 'facet face ; (read in english: "take 'facet from face") |
Graham, try a different port, maybe it's port2 that is mapped in your system. | |
modem: open/lines/no-wait/direct serial://port2/9600/8/none/1 ; from an example on rebol-list 2003-12-03 | |
Graham 12-May-2005 [1074] | I meant above that I also tried serial://com1/9600/8 ... |
Anton 13-May-2005 [1075] | Well, I was just able to do this with no error: >> port: open serial://port2/9600/8 >> close port |
Graham 13-May-2005 [1076x2] | wonder what's wrong with mine. |
I wonder if I have the serial printer attached as a windows printer and it's hogging the serial port. | |
Anton 13-May-2005 [1078] | Check whether it's enabled in device manager |
Graham 13-May-2005 [1079x2] | the serial port currently has a serial printer attached |
which is working. I am trying to send some commands to the printer | |
Anton 13-May-2005 [1081x2] | are you trying to communicate with the printer ? |
right ok. | |
Graham 13-May-2005 [1083] | yes |
Anton 13-May-2005 [1084] | You need something to see the status of all ports on your system to diagnose, I think, but it looks like, if rebol can't open it, that windows already has opened a port to it. |
Graham 13-May-2005 [1085x4] | yep, that was it. |
I removed the serial printer from the windows printers and now I can open the port | |
now, how do I send a page feed to the printer ... ? | |
That's 0c isn't it? | |
Anton 13-May-2005 [1089x2] | You could probably just disconnect the serial cable physically, then scan for hardware changes... can save time later on maybe.. |
Yep, looks like FormFeed (FF) is 0x0C | |
Graham 13-May-2005 [1091x2] | oh well, it doesn't do what I need it to do. |
tried insert port #{0c} but the paper won't feed :( | |
Anton 13-May-2005 [1093x2] | Maybe you need to terminate your commands.. ? See if you can find the language that the printer understands. |
(and maybe there's a "simple mode" and a "windows mode" the printer can go into) | |
Gregg 13-May-2005 [1095x2] | That is pretty crazy Allen. Doesn't seem like it could be too hard to do. |
Graham, in the old days you would use the Escape+passthrough API, but that's been frowned on for quite a while now. Have you tried writing to %//PRN ? With more API work (OpenPrinter), you can use spooler functions like EndPagePrinter or WritePrinter too. | |
Graham 13-May-2005 [1097] | the problem is I don't have a windows driver for this printer so I am experimenting to see what type of controls it understands. There is no manual, and the windows drivers are password protected on the manufacturer's website! |
DideC 13-May-2005 [1098] | Give us the printer model. May be someone here... |
Graham 13-May-2005 [1099x3] | I doubt it .. but here it is .. Addmaster IJ3000 |
http://www.addmaster.com | |
It looks like it accepts similar escape sequences as esc/pos ... but the application I'm using won't flush the printer buffer without closing the application down. | |
Gabriele 13-May-2005 [1102] | graham: check the serial parameters |
Graham 13-May-2005 [1103] | Let me rephrase that. I am using a POS program which I downloaded. When it prints a receipt to my serial printer, it fails to cause the printer to print the full printer buffer. But when I close the POS program down, the printer then spits out the rest. I have downloaded the Builder C++ source ( but it won't compile without errors :( ). I thought I would try and use Rebol first to send commands to the printer to see what I need to do to force the printer to print the contents of it's buffer. It's not the pc buffer as I turned off the fifo buffers in the serial port settings to see what the problem was. |
sqlab 13-May-2005 [1104x2] | Does your printer finish the job, if your POS program sends a new page or a new job? Can you manually force a linefeed on your printer? |
Sorry, I meant Can you force a FF formfeed on your printer? | |
Sunanda 13-May-2005 [1106] | If you can issue a DOS command (REBOL/Command or some betas with Call enabled), try this: echo ^l > prn (That's a ctrl+L character, not a caret then L) That should force a form feed |
older newer | first last |