Sunanda
7-May-2005
[1028]
Gordon, your method only works for chars than happen to map to decimals. 
 Try this for an error:

print to-integer to-string to-hex to-integer to-decimal to-char "M"


Variant on Tom's to produce the same result as yours (may not work 
with 64-bit REBOL)
     form skip to-hex to-integer first "a" 6
Gordon
7-May-2005
[1029]
Thanks Tomc and Sunanda
Tomc
7-May-2005
[1030x2]
>> copy/part tail to-hex to integer! to char! "Z" -2
== #5A
unfortinatly for me we dont have a 64 bit rebol
Gordon
7-May-2005
[1032]
Does anyone?
Tomc
7-May-2005
[1033x2]
or unicode
not that I know of
Gordon
7-May-2005
[1035]
Thanks again for your help
Sunanda
7-May-2005
[1036x2]
Quick work there Gordon:

http://www.rebol.org/cgi-bin/cgiwrap/rebol/view-script.r?script=char-to-hex.r
Thanks for the name check :-)
And I see you've solved the potental 64-bit / variable hex problem
Gordon
7-May-2005
[1038x5]
Well actually Tomc made the suggestion.
Sorry for the slow reply but if I leave Altme open it keeps stealing 
focus from my coding program .  I have to shut Altme down so I can 
work.
Here's another odd one that has be puzzled

(Notice that appending something to the Writefile variable, also 
appends it to the DateStr variable!  Very Strange!)

>> WriteFile: "WriteFileName_2005-05-07"
== "WriteFileName_2005-05-07"
>> DateStr: skip tail WriteFile -10
== "2005-05-07"
>> Success: append WriteFile "_Parsed.txt"
== "WriteFileName_2005-05-07_Parsed.txt"
>> probe DateStr
2005-05-07_Parsed.txt
== "2005-05-07_Parsed.txt"
Nevermind.  I think I should have used a copy of Writefile.  DateStr 
must be a subset of  WriteFile variable because of the reference 
to it's tail.
Yep, it just  needed a copy as in:
>> DateStr: skip tail copy WriteFile -10
== "2005-04-11"
Tomc
8-May-2005
[1043]
gordon:  home-icon - settings - options -unset  "activate window 
on new message"
Gordon
8-May-2005
[1044]
Thanks Tomc; that should do it.
Micha
9-May-2005
[1045x3]
how to decode this url ?
input: uggc%2Fjungvfzlvc.pbz
output: http://whatismyip.com
Anton
9-May-2005
[1048]
rot13: func [s [string!] /local result top][
    result: copy s
    repeat n length? s [

        top: either s/:n >= #"a" [97][65] ; determine upper or lowercase

        if (i: s/:n - top) < 26 [ ; only 26 letters in alphabet affected
            i: i + 13 // 26 ; perform rot13
            poke result n to-char top + i ; insert new letter
        ]
    ]
    result
]
Gabriele
9-May-2005
[1049x5]
sunanda: i can only think of:
>> index? find (as-binary a) xor as-binary b complement charset "^(00)"
== 7
though, i'm not sure it's an easy way, and it is probably overkillif 
a and b are "big".
another option would be to try with parse, though it's gonna boil 
down to some kind of loop anyway.
>> parse a [any [(char: b/1) char (b: next b)]]
== false
>> b
== "45678"
Janeks
9-May-2005
[1054]
How to set correctly progress function for read-net? Or what causes 
following error and :                                            
                >> myProgr: func [ tot bt ] [ print bt / tot ]

>> read-net/progress to-url "http://maps.dnr.state.mn.us/cgi-bin/mapserv36?map=/usr/loca

l/www/docs/mapserver_demos/tests36/expressions/test.map&map_counties_class_expression=(%

5bAREA%5d %3e 7577272785.15339)&layer=title&map_title_class_text=Counties+Larger+Tha
n+Itasca+County&mode=map" :myProgr
0.425625
** Script Error: not is missing its value argument
** Where: read-net

** Near: all [:callback size not callback size length? buffer data: 
true break]
not data
>> source read-net
read-net: func [

    {Read a file from the net (web). Update progress bar. Allow abort.}
    url [url!]

    /progress callback {Call func [total bytes] during transfer. Return 
    true.}
    /local port buffer data size
][
    vbug ['read-net url]
    if error? try [port: open/direct url] [return none]

    size: to-integer any [port/locals/headers/content-length 8000]
    buffer: make binary! size

    set-modes port/sub-port [lines: false binary: true no-wait: true]
    until [
        if not data: wait [60 port/sub-port] [data: true break]
        if data: copy port/sub-port [append buffer data]

        all [:callback size not callback size length? buffer data: true break]
        not data
    ]
    close port
    if not data [buffer]
]
>>
Gabriele
9-May-2005
[1055]
is your callback function returning a value? i think it should return 
true normally, or false if you want to cancel the download.
Allen
9-May-2005
[1056]
Use request-download as a guide. It has everything you need to know. 
you should be able to substitute read-thru with read-net if you wish.
Janeks
10-May-2005
[1057x3]
O'k. My mistake are offen do not tell what is my target. So it is 
to get working status bar in a layout. As I understood it is possible 
by read-thru.
Thanks Gabriele. It was the reason. But to continue regarding status 
bar functions fired by read-thru. Than it is a problem just to kBox/image: 
 read-thru/progress myUrl :myProgr . It is possible just by using 
local file i.e. kBox/image: read-thru/to/progress myUrl %tmpImg.png 
:myProgr
BTW: How to insert newline in a post?
DideC
10-May-2005
[1060]
Click the "pen" icon just up to the input area (near color/ no color 
one)
Janeks
10-May-2005
[1061]
Thanks!
I am getting following parameters of myProgr:
3650 8000
7430 8000
9950 8000
13730 8000
15335 8000
19115 8000
22975 8000
26755 8000
30695 8000
34475 8000
38255 8000
42195 8000
46055 8000
49835 8000
53695 8000
55197 8000
55197 8000


How then to calculate data for progress bar ( decimal from 0 to 1 
)?
Or how to get total bytes?
Allen
10-May-2005
[1062]
Janek. request-download has the example callback you need. View its 
source. here is a snippet. Where prog is the progressbar and stat 
is a label in your layout and stop is a value that controls that 
should be be set false outside of this func to start with, and can 
set to true via a cancel button to force a download to stop before 
completion. 
func [total bytes] [
        prog/data: bytes / (max 1 total) 
        stat/text: reform [bytes "bytes"] 
        show [prog stat] 
        not stop
    ]
Janeks
11-May-2005
[1063]
Thanks Allen!
The problem was so obvious that I did not think about it ;-)

just it is impossible to know what size of image will be that is 
coming from a cgi process with many parameters.
Allen
11-May-2005
[1064]
A easy job for REBOL... http://www.eyon.com/. I can't believe this 
tool needs to be 4mb zipped.
Volker
12-May-2005
[1065]
i like this little function and cant find a good name.
your: func [offset value] [
	if value [value/:offset]
]
usage:
 your 'facet get-style 'field

its sometimes more readable IMHO than putting the interesting word 
far at the end of line.
but i find no good name.. any suggestions?
RebolJohn
12-May-2005
[1066]
Help peoples..

I have the following..
  x: [a b c d]

  foreach y x [ set y make string! {} ] ;make them all empty strings.
then I process/append info into the different groups a,b,c,d.
Now, I want to write each string/list to a file of the same name.
i.e.
  foreach y x [write to-file join y ".txt" ??GETVALUE?? y]

Can someone clue me in on what I do at the ??GETVALUE?? position?

Thanks peoples.
Sunanda
12-May-2005
[1067x2]
foreach y x [print [y get y]]
... so the missing ??getvalue?? is just get
Graham
12-May-2005
[1069x2]
How does one open up the serial port?


I've tried open serial://port1/9600/8 and serial://port1/9600/8 and 
both give me errors ..
this is in windows
Anton
12-May-2005
[1071x3]
Volker, in english, it seems better to write
	'facet of face    (where OF is the function in between)
but we can't do that...
How about TAKE ? ie.
	take 'facet face    ; (read in english: "take 'facet from face")
Graham, try a different port, maybe it's port2 that is mapped in 
your system.
modem: open/lines/no-wait/direct serial://port2/9600/8/none/1  ; 
from an example on rebol-list 2003-12-03
Graham
12-May-2005
[1074]
I meant above that I also tried serial://com1/9600/8 ...
Anton
13-May-2005
[1075]
Well, I was just able to do this with no error:
>> port: open serial://port2/9600/8
>> close port
Graham
13-May-2005
[1076x2]
wonder what's wrong with mine.
I wonder if I have the serial printer attached as a windows printer 